2015 Touring – TEMPERATURE MANIFOLD ABSOLUTE PRESSURE SENSOR (TMAP) – INSTALLATION

1. Inspect O-ring on pressure port for cuts, tears or signs of deterioration. Install new O-ring if necessary.

2. With the electrical connector facing toward the rear of the induction module, insert pressure port on TMAP sensor into hole in induction module.

3. Align hole in TMAP sensor bracket with threaded hole in induction module.

4. Install new hex screw and tighten to 58-64 in-lbs (6.6-7.2 Nm).

5. Install fuel tank. See 4.6 FUEL TANK.

 