Removal
NOTE
Maximum current rating for each switch is 2A.
1. Remove instrument bezel. See 2.40 INSTRUMENT BEZEL: FRAME MOUNTED FAIRING MODELS.
2. See Figure 7-56. Remove two screws (3). Remove switch module or hole plug (1).
NOTES
• Record positions of switches and plunger types for assembly.
• The switch module assembly can house either active switch plungers or static plungers depending on equipment. Active plungers can be push-push type or momentary. All are removed and installed in the same manner.
• See Figure 7-55. Lock (3) extracts approximately 1/8 in (3.2 mm) and does not come free from housing.
3. Gently pry lock (3) outward to release switch plunger (2).
4. Remove switch plunger from switch module.
Installation
1. See Figure 7-55. Push plunger (2) into switch module.
Push lock (3) into place.
NOTE
Verify that switches are located as recorded during disassembly.
2. See Figure 7-56. Secure switch module (1) with two screws (3). Tighten to 12-17 in-lbs (1.4-1.9 Nm).
3. Install instrument bezel. See 2.40 INSTRUMENT BEZEL: FRAME MOUNTED FAIRING MODELS.
4. Operate all switches to verify repair.